Manually Override The Shutter - Christie CP2215 Service Manual

Hide thumbs Also See for CP2215:
Table of Contents

Advertisement

Adjust the Image

Manually Override the Shutter

Use this procedure to override the shutter when it remains partially open or closed. When time
permits, replace the shutter assembly.
1. Turn the lamp off and allow the projector to cool for 15 minutes.
2. Remove the lens. See
3. Reach through the lens opening and move the shutter up and down 3 times.
4. Tap the douser open and close icons on the touch panel controller and determine if the douser is
operating.
If the douser is not operating:
a. Turn the projector off and then disconnect it from AC power.
b. Remove the top lid. See
c. Remove the high security lid. See
page 24.
d. Disconnect the douser from the IMCB.
e. Move the douser to the open or closed position.
5. Replace the high security lid and the top lid.
6. Replace the lens.
7. Reconnect the projector to AC power and turn it on.
18
Remove the Lens
on page 31.
Remove the Top Lid
Remove the High Security and Light Engine Lid
on page 22.
020-101226-03 Rev. 1 (10-2015)
on
CP2215 Service Manual