Align The Fold Mirror - Christie CP2215 Service Manual

Hide thumbs Also See for CP2215:
Table of Contents

Advertisement

Adjust the Image
5. Loosen the 2 integrator rod set screws.
6. If the image is not parallel to the screen, rotate the integrator rod.
7. If the edges of the image are not in focus, loosen the two set screws on the end of the optical
housing and then move the handle attached to the lens backward and forward.
8. Verify no shadows are on the screen. If shadows appear, see
9. Tighten all of the integrator rod set screws.
10. Replace the top lid.

Align the Fold Mirror

If a corner or edge of an image is missing, the fold mirror might be misaligned with the optical
system. To correct this issue:
1. Remove the top lid and set it aside. See
2. Display a full white test pattern:
a. On the touch panel controller (TPC), tap the Test Pattern icon (
b. Tap All Test Patterns.
c. Tap RBG-12bit-Full Screen White.
8
Align the Fold Mirror on page
Remove the Top Lid
on page 22.
8.
) in the taskbar.
CP2215 Service Manual
020-101226-03 Rev. 1 (10-2015)

Advertisement

Table of Contents
loading

Table of Contents