Chapter 7 Waveform Acquisition

7.1

Starting/Stopping Waveform Acquisition

Procedure
X-Y
SETUP
DISPLAY
MEASURE
CURSOR
MENU
MENU
PRINT
IMAGE SAVE
HISTORY
Explanation
Operation When the Acquisition Mode Is Set to Averaging Mode
START/STOP Operation during Accumulation
Events that Disable the START/STOP key
IM 701450-01E
FILE
MISC
RESET
SELECT
PHASE
GO/NOGO
MATH
SHIFT
ACQ
START/STOP
Press START/STOP.
Waveform acquisition is in progress when the indicator above and to the right of the
key is illuminated. When waveform acquisition is stopped, the indicator is OFF and
"Stopped" is displayed at the upper left corner of the screen.
When waveform acquisition is started, waveform data is stored to the acquisition
memory each time a trigger is activated, and the displayed waveform is updated. The
acquisition memory is divided by the specified record length, and the maximum number
of waveforms that can be acquired is retained. The past waveforms that have been
retained can be recalled and displayed using the history memory function when
waveform acquisition is stopped. For the procedure of recalling waveforms using the
history memory function, see section 10.1.
• Averaging is stopped when waveform acquisition is stopped.
• Averaging starts again when waveform acquisition is restarted.
Accumulation is aborted when acquisition is stopped.
When acquisition is started, the accumulated waveforms up to that point are cleared, and
new accumulation is started.
• When remote mode is engaged using the communication interface.
• When printing, during auto setup, and while the storage medium is being accessed.
Note
Pressing the FILE key or HISTORY key while acquiring waveforms stops waveform
acquisition.
If you start waveform acquisition after changing the waveform acquisition conditions, the data
that had been stored in the acquisition memory up to that point is cleared.
A snapshot function that keeps the current displayed waveform on the screen is also
available. You can update the display without stopping waveform acquisition (see section
8.6).
• To exit the menu during operation, press ESC located
above the soft keys.
• For a description of the operation using a USB keyboard or
a USB mouse, see section 4.3.
7