Type Description; Models; Options - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

Each Timer is as so ci ated with a Timer Event on the
Events-Ac tions page.
When the Timer trig gers the ON sig nal, the cor re spond -
ing Event will oc cur (e.g. the Gar den Sprin kler will turn
ON).
When the Timer trig gers the OFF sig nal, the cor re -
spond ing Event will be ter mi nated (e.g. the Gar den
Sprin kler will turn OFF).
The ON/OFF op er a tions of each Timer will be re corded
in the log, as fol lows:
Type: Timer ON or Timer OFF
IDENT.: Timer De scrip tion
TIME: Time and Date of the ON and OFF op er a tions
The Timers can be pro grammed with the ON/OFF
Times of do mes tic ap pli ances such as Gar den Sprin -
klers, Cour tesy lights, Heating sys tems, etc., or with the
AC TIVE/IN AC TIVE Times of the sys tem Out puts,
Codes and Keys.
The user can en able/dis able the Timers (re fer to
"En./Dis. Timers" in the USER MANUAL).
If a User dis ables a Timer dur ing its pro grammed ON
Time, the cor re spond ing Timer event will end.
If a User en ables a Timer dur ing its pro grammed ON
Time, the cor re spond ing Timer event will start within the
min ute.
Ex am ple: If a Timer — with a pro grammed ON Time of
21.00 to 24.00 — is en abled at 22:02:01 the cor re -
spond ing Timer event will be trig gered at 22:03:00
The EN ABLE/DIS ABLE op er a tions of each Timer will
be re corded in the log, as fol lows:
Type: Timer En abled or Timer Dis abled
IDENT.: Timer De scrip tion
USER: Key pad De scrip tion
USER ID.: Code De scrip tion
TIME: Time and Date of the ON and OFF
op er a tions
The Timers page will al low you to pro gram
the Timer pa ram e ters, as fol lows.
Se lect the re quired Day Model, then se lect
the tag of the Day model timer you wish to set
up, in the lower part of the ta ble.
No. This non-editable field shows the Timer ID
Num ber.
Description En ter the respective Timer la bel
(e.g. Heater, Sprin kler, etc.). This la bel will be
used to iden tify the Timer in all the op er a tions
it is in volved in.
1st ON / 2nd ON / 3rd ON / 4th ON This
field will al low you to set the ON Time (re fer to
1st Dis. / 2nd Dis. / 3rd Dis. / 4th Dis. for the
Time for mat).
74
1st OFF / 2nd OFF / 3rd OFF / 4th OFF This field will
al low you to set the OFF Time (re fer to 1st Dis. / 2nd
Dis. / 3rd Dis. / 4th Dis. for the Time for mat).

Type Description

Refer to "Types De scrip tion" un der "Sched uler - Tim ers".

Models

Re fer to "Models" and "Events" un der "Sched uler -
Timers".

Options

This page will al low you to setup the op tions that de ter mine
the op er at ing mode of the sys tem.
Disable Tamper Memory Reset with User code
If this op tion is en abled, only the In staller Codes will be
able to de lete the Zone, Par ti tion and Con trol Panel
Tam per mem o ries.
Maintain Zone Test Attribute If this op tion is en -
abled, any Alarms gen er ated by Zones in Test sta tus
will be re corded in the Events log, also when the Par ti -
tion is Dis armed.
Enable dynamic battery test timeout after mains restoral
Af ter pro vid ing power dur ing a Mains black out, the bat -
tery will be quite low, and there fore, un able to meet the
Dy namic Bat tery Test re quire ments (re fer to "Power
sup ply con nec tion" un der "In stal la tion"). If this op tion is
en abled, the Dy namic Bat tery Test will re start 5 hours
af ter Mains restoral (in stead of im me di ately) thus al low -
ing the bat tery to re charge.
Disable Alarm Memory Reset With Installer Code
If this op tion is en abled, only en abled User Codes will
be able to de lete Alarm mem o ries.
Fig ure 48 Op tions page