7. Set the op er at ing mode for the tam per switch and
snatch microswitch us ing jumper 97:
oo = Tam per and Snatch switches en abled ;
// = Tam per and Snatch switches dis abled.
8. Set the op er at ing mode us ing microswitches 6 and
7 on DIP switch 80 as shown in the fol low ing ta ble:
Microswitch No.
6
7
OFF
OFF
In put Ex pander with 6 In puts
ON
OFF
In put Ex pander with 4 In puts +
Out put Ex pander with 2 Out -
puts (T1 and T2 Out puts; T3,
T4, T5 and T6 In puts)
OFF
ON
Out put Ex pander with 4 Out -
puts + In put Ex pander with 2
In puts (T1, T2, T3 and T4 Out -
puts; T5 and T6 In puts)
ON
ON
Out put Ex pander with 6 Out puts
9. Set the op er at ing mode of the In puts us ing
microswitch 8 on DIP switch 80 as shown in the fol -
low ing ta ble:
Microswitch
No.8
All In puts op er ate in Nor mal
OFF
mode
All in puts func tion as in ter face
ON
for Roller blind con tact.
10. Re place the frontplate.
Be care ful about the po si tion of con duc tive pin 108,
lo cated in side the cover: it must close the Tam per
switch Con tact 98 on the PCB (com po nent side).

Terminals

This sec tion de scribes the Main Unit and BPI de vice ter -
mi nals.
The lay out of Ter mi nal De scrip tion ta ble is as fol lows:
the Ter. col umn shows the ter mi nal iden ti fier;
the DESCRIPTION col umn pro vides a brief de scrip -
tion of each ter mi nal;
the v(V) col umn shows the ter mi nal volt age (the hy -
phen "–" in di cates that the volt age can not be spec i -
fied for the ter mi nal concerned);
the I(A) col umn shows the max i mum cur rent (in Am -
peres) that can cir cu late on the ter mi nal (the hy phen
"–" in di cates that the cur rent can not be spec i fied for
the ter mi nal con cerned);
the num bers in brack ets re fer to the fol low ing notes.
KYO320
OPERATING MODE
OPERATING MODE FOR
INPUTS
(1) The to tal cur rent draw of Main Unit ter mi nals [+A3],
[+N3], [+A2], [+N2], [+A1], [+N1], [+B4], [+B5], [+F],
[+F1], [+] and [RED] must not ex ceed 3.8A for KYO320.
(2) The cur rent draw of BPI de vice [+] ter mi nals is:
Key pad = 0.05 A for MIA-D, and 0.04 for
ALISON-DVP and Alison-S(B029), 0.07A for
Alison32LP
Reader = 0.03 A
M-IN/OUT In put/Out put Ex pander = 0.02 A.
These val ues re fer to the cur rent draw of the BPI
de vices with no loads.
(3) The sum of the cur rents ab sorbed by the ter mi nals
[+F] of an M-IN/OUT In put/Out put Ex pander must not
ex ceed 0.4 A.

Main Unit

Ter.
NA3
Pro gram ma ble
NC3
(change over switch con tacts)
C3
+A3 Pro gram ma ble Out put no.3 (pos i -
tive), pro tected by fuse
+N3 Pro gram ma ble Out put no. 3 (in -
trin sic se cu rity), pro tected by fuse
NA2
Pro gram ma ble
NC2
(change over switch con tacts)
C2
+A2 Pro gram ma ble Out put no. 2 (pos i -
tive), pro tected by fuse
+N2 Pro gram ma ble Out put no. 2 (in -
trin sic se cu rity), pro tected by fuse
NA1
Pro gram ma ble
NC1
(change over switch con tacts)
C1
+A1 Pro gram ma ble Out put no. 1 (pos i -
tive), pro tected by fuse
+N1 Pro gram ma ble Out put no. 1 (in trin -
sic se cu rity), pro tected by fuse 46
+B4 Pos i tive power sup ply to pe riph er -
als, pro tected by fuse
pow ered by the bat tery dur ing
Mains fail ure)
+B5 Pos i tive power sup ply to pe riph er -
als, pro tected by fuse
pow ered by the bat tery dur ing
Mains fail ure)
M Neg a tive
OC1 Pro gram ma ble
(Open-Col lec tor)
OC2 Pro gram ma ble
(Open-Col lec tor)
OC3 Pro gram ma ble
(Open-Col lec tor)
AS 10 KΩ Balance Tam per Line
L1
Pro gram ma ble In put Line
:
L8
INSTALLING
DESCRIPTION
Out put
no.
3
Out put
no.
2
Out put
no.
1
(will be
(will be
Out put
no.
4
Out put
no.
5
Out put
no.
6
v(V) I(A)
3
13.8 3(1)
13.8 3(1)
3
13.8 3(1)
13.8 3(1)
3
13.8 3(1)
13.8 3(1)
13.8 3(1)
3(1)
0
0
1
0
1
0
1
17