Thermal Probe - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

Thermal Probe

This Con trol panel has an on-board con nec tor 31 for a
KST ther mal probe (ac ces sory item). The probe will op -
ti mize the backup bat tery charge pro cess, by reg u lat ing
the charge volt age in ac cor dance with the tem per a ture
of the backup bat tery.
Work care fully through the fol low ing in struc tions (re fer
to the fig ure on page 10):
1. Con nect the probe 9 to the con nec tor 62 (PTC) on
the Switch ing Power sup ply.
2. At tach the probe to the backup bat tery, in such a
way as to ob tain op ti mum heat trans fer.
3. Con nect the con nec tor of backup bat tery 53 on
the PCB.
4. Mea sure the Probe tem per a ture.
5. Using the graph in Fig ure 25 and/or Ta ble 3, find
the value (in ac cor dance with the bat tery tem per a -
ture) that the Switching Power sup ply out put volt -
age will be based on.
6. Using the trim mer 54, ad just the volt age on the ter -
mi nal board 55 to the re quired value.
a)
14,5
14,0
13,7
13,5
13,0
-10
Fi gu re 25 Switching Power Sup ply Out put Volt age graph. To find the Out put Volt age us ing the graph: — in di cate the
Probe tem per a ture on the TEM PER A TURE (°C) axis; draw a line from the tem per a ture value point up to the curve a);
draw a line from the in ter sec tion point across to the VOLT AGE (V) axis; ad just the Out put Volt age of the Switching
Power Sup ply to the re sul tant value. For ex am ple, if the Probe tem per a ture is 22 °C, the Out put Volt age of the
Switching Power Sup ply must be set at 13.7 V.
TEMPERATURE (°C)
VOLTAGE (V) 14.5
Ta ble 3 Switching Power Sup ply Out put Volt age chart. To find the Out put Volt age us ing the chart: — se lect the near -
est value to the Probe tem per a ture on the TEM PER A TURE (°C) row; read the cor re spond ing value on the VOLT AGE
(V) row; ad just the Out put Volt age of the Switching Power Sup ply to the in di cated value. For ex am ple, if the Probe tem -
per a ture is 22 °C, the Out put Volt age of the Switching Power Sup ply must be set at 13.7 V.
30
-5
0
5
10
-10
-5
0
5
14.4
14.3
14.1
15
20
22
25
30
TEMPERATURE (°C)
10
15
20
25
14.0
13.9
13.7
13.6
35
40
45
50
30
35
40
45
13.5
13.4
13.3
13.2
50
13.1