Enable Test Event; Installer Maintenance - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

+
The application will assign the first four Telephone
Numbers in the General book (Telephone page)
to the Teleservice function. If you do not wish to
use the preset numbers, Disable the correspond-
ing Enable option.
Telephone Number to call Select
Telephone Numbers from the General book on the
Telephone page.
+
Disabled Telephone Numbers will not be called.
Customer Code This Code will allow the Central Sta -
tion to identify the Control Panel.
+
Any changes made to the Customer code on the
Teleservice page will affect the Customer code in
the Customer Data window and vice versa.
Attempts This programming field will allow you to pro-
gram the maximum number of call attempts.
Valid entries: 1 through 99
At default: 8
n Enable Test Event
If this option is Enabled, the Control panel will make
regular Test Calls. The Test call confirms that the Con-
trol Panel is operating properly. If the Control panel fails
to transmit to the Central station for a long period, it may
mean:
— the system is operating properly but no events have
occurred or,
— there is a breakdown in transmissions.
If the Central station does not receive the Test Call at
the set time, it will be assumed that there is a break-
down in transmissions.
To set up the Test call, use the Test event and/or
Teleservice, as follows.
Enable Test Call If this option is Enabled, the Control
Panel will make the Test call at regular intervals, in accor-
dance with the First Test and Repeat test event settings.
+
If the Enable Test Event is Disabled, the
Control panel will not send the Test call.
Enable Test Event If this option is Enabled,
the Control panel will generate the Test event
in accordance with the First Test and Repeat
test event parameters.
If this option is Disabled (at default), the Test
event will be inhibited.
First Test This programming field is for the
date and time of the first Test.
+
Subsequent Test calls depend on the Re -
peat test event setting.
Repeat test event This programming field is
for the interval between Test calls.
54
the
Teleservice
Figure 40 Teleservice page
Initialize If you are downloading a new Test setting to
the Control panel, you must select this button, other -
wise the new setting will be ignored.
+
If the entered date and time are prior to the current
date and time on the computer, the Initialize button
will be inhibited. The Control Panel must be con-
nected to the PC via serial port or telephone.
n Installer Maintenance
The Installer Maintenance section will allow you to
program the date and time of Installer Maintenance Re-
quest signal.
The Installer Maintenance Request will be signalled by the:
Ø Installer Maintenance event;
Ø ON status of the G indicator on the keypad.
+
The Trouble indicator G signals various Trouble
events. The Trouble details can be found on the
LCD Keypads (in View Mode). If the trouble is re -
lated to an Installer Maintenance Request, the re -
spective message will be shown (see the
Description field in the Installer Maintenance
section).
The Trouble signal generated by the Installer Mainte -
nance Request and Installer Maintenance will termi -
nate when:
Ø the Teleservice page is downloaded;
Ø the Date and Time of Installer Maintenance are pro -
grammed at the Keypad (refer to "Teleservice" in the
KEYPAD PROGRAMMING MANUAL).
To set up the Installer Maintenance Request — Enable
the Maintenance Request option and set the Date and
Time, as follows.
Date Enter the date of the Installer Maintenance Re -
quest signal.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents