Locating The Chassis Serial Number; Locating A Failed Component (Bui); Locating A Failed Component (Cli) - Oracle ZFS Storage Appliance Service Manual

Zs3-x series, 7x20 series
Hide thumbs Also See for ZFS Storage Appliance:
Table of Contents

Advertisement

Locating the Chassis Serial Number

"Locating a Failed Component (BUI)" on page 34
"Locating a Failed Component (CLI)" on page 34
Locating the Chassis Serial Number
To obtain support for your storage controller or to order new parts, you need your chassis serial
number. There are three ways to locate the chassis serial number
1.
You can find a chassis serial number label on the storage controller front panel
on the left side. Another label is on the top of the storage controller.
2.
You can click the Sun/Oracle logo in the BUI masthead to obtain the serial
number.
3.
You can use the following CLI command:
hostname: maintenance hardware show

Locating a Failed Component (BUI)

Use the following procedure to locate a failed component using the BUI.
1.
Go to the Maintenance > Hardware screen.
2.
Click the right-arrow icon
fault icon.
Locate the fault icon in the lists of hardware components, and click it. The image
3.
should be updated to show where that component is physically located.
4.
(Optional) Click the locator icon
The LED on the component will begin to flash.

Locating a Failed Component (CLI)

Use the following procedure to locate a failed component using the CLI.
34
Oracle ZFS Storage Appliance Customer Service Manual • July 2016
on the Storage System or Disk Shelf which has the
for that component, if the component has it.