Replacing A Zs3-2 Hdd Or Ssd - Oracle ZFS Storage Appliance Service Manual

Zs3-x series, 7x20 series
Hide thumbs Also See for ZFS Storage Appliance:
Table of Contents

Advertisement

Replacing a ZS3-2 HDD or SSD

2.
Using your thumb and middle finger, apply a slight downward pressure while
pulling the plug out of the port. Do not pull the plug upward or pinch the release
tab with your fingers below the plug, as shown below.
Replacing a ZS3-2 HDD or SSD
HDDs and SSDs are hot-swappable and can be removed and installed while the storage
controller is running without affecting other hardware capabilities. Use the following procedure
to replace a ZS3-2 HDD or SSD. For information on disk compatibility, see the
Handbook.
Note -
than one drive in quick succession causes a hardware/pool fault. Also, do not perform a pool
configuration operation while a disk firmware upgrade is occurring. To check if an upgrade is
in progress, navigate to Maintenance > System in the BUI, or maintenance system updates in
the CLI.
1.
Identify the failed drive by going to the Maintenance > Hardware section of
the BUI and clicking the drive information icon
system, the amber Service Required indicator on the HDD or SSD should be
illuminated.
130
Oracle ZFS Storage Appliance Customer Service Manual • July 2016
If you have more than one failed drive, replace only one drive at a time. Removing more
Oracle Systems
. If you are physically at the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs4-4Zs3-473207120De2-24Sun diskshelves ... Show all

Table of Contents