Replacing a ZS3-2 PCIe Card or Riser

24.
After the SP status indicator is solid green, use a pen or other pointed object to
press and release the recessed Power button on the front panel. The Power/OK
status indicator next to the Power button lights and remains lit.
25.
Go to the Maintenance > Hardware screen of the BUI. Click the right-arrow icon
for the controller and then click DIMM to verify that the online icon
green for the newly installed DIMM.
26.
If a fault does not self-clear, see
Replacing a ZS3-2 PCIe Card or Riser
Caution -
discharge, which can cause the component to fail. To avoid damage, wear an antistatic wrist
strap and use an antistatic mat when handling components.
Removing a PCIe card is a cold-service operation. You must power off the appliance before you
remove the card. There will be a loss of access to the storage unless the system is in a clustered
configuration.
To locate a faulted component, go to the Maintenance > Hardware screen of the
1.
BUI and click the right-arrow icon
2.
Power off the storage controller as described in
Controller" on page
Disconnect the AC power cords from the rear panel of the storage controller.
3.
Caution -
the power cords before accessing any cold-serviceable components.
4.
Extend the controller from the rack as described in
Controller from the Rack" on page
5.
Remove the top cover as described in
6.
Locate the PCIe card position in the storage controller, see
Cards" on page
146
Oracle ZFS Storage Appliance Customer Service Manual • July 2016
This procedure requires that you handle components that are sensitive to static
50.
Because 3.3 VDC standby power is always present in the system, you must unplug
169.
"Repairing Active Problems" on page
on the controller, and then click Slots.
"Powering Off the
"Extending the Storage
51.
"Removing the Top Cover" on page
is
37.
52.
"ZS3-2 PCIe I/O