Alarm_MD_ModuleParametersCorrupt
Alarm_MD_Phasefail
Alarm_MD_PowerbusHighResistant
Alarm_MD_Supplylimits
Alarm_MD_Systemoverload
Alarm_MD_SystemParametersCorrupt
Alarm_MR_ModuleParametersCorrupt
Alarm_MR_MoreCapableModuleDetected Boolean
Alarm_MR_NewModuleDetected
Alarm_MR_Systemoverload
Alarm_MR_SystemParametersCorrupt
Alarm_MR_SystemShutdown
Alarm_MR_SystemStateBuffering
Alarm_MR_SystemStateCooledDown
Alarm_MR_SystemStateReadyForRestart
Alarm_MR_UnexpectedModuleDetected
Alarm_MR_Output1InterruptionShut
downInitiated
Power supply system PSU8600
Manual, 05.2017, A5E36758446-3-76
Data type
Definition
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Boolean
Sitop_8600_AlarmType
Engineering and remote access
7.8 OPC UA server
Description
Stored module configuration is
corrupt. Deviating module behavior
may be possible.
Phase failure or unbalanced supply
voltage detected. Operation can
continue for a limited time.
High-resistance internal supply
detected. Check connections!
Supply voltage is outside the nomi-
nal limits. Automatic derating (lim-
ited performance) can occur when
the voltage is low.
System load current detected with-
in the permissible overload profile.
Operation can continue for a brief
period.
Stored system configuration cor-
rupt. Deviations from the expected
response may occur outside nor-
mal operation.
Stored module configuration is
corrupt. Module behavior remains
consistent, however.
A module with excessive power
was detected. Normal system op-
eration is possible.
New unconfigured module detected
System load current is above the
specified warning threshold. Op-
eration can continue without re-
strictions.
System configuration is different.
The system can be operated.
General error occurred. Device
behavior remains consistent, how-
ever.
The power supply system is sup-
plied via the buffer expansion
module(s).
System can be switched on again
after automatic shutdown due to
impermissible operating condition.
Reset by switching the supply
voltage off and on.
System is ready to switch on again.
Unexpected module type detected
The shutdown of output 1 has been
initiated in the course of the out-
put 1 interruption sequence.