Data
Energy_Consumption_To_Pause [kWh]
Energy_Consumption_To_Operate [kWh]
Index 49: PROFIenergy channel list (reading/writing)
Data
ChannelsOffList
Index 53: Web server (reading/writing)
Data
WebserverEnabled
AutoReloadEnabled
ReloadTime
AutoLogout
HttpAccessEnable
Power supply system PSU8600
Manual, 05.2017, A5E36758446-3-76
Description
-
-
Description
Overview of the outputs that are shutdown. Each
output is represented using 1 bit (starting with bit 0
for output 1).
Description
Activating/deactivating the web server of the
SITOP PSU8600:
0: disable
•
255. enable
•
Enable/disable automatic update:
0: disable
•
255. enable
•
Update interval:
0: Off
•
5: 5s
•
10: 10s
•
20: 20s
•
30: 30s
•
60: 60s
•
Enable/disable automatic logoff:
0: disable
•
255. enable
•
When automatic logoff is activated, the logged on
user ("Guest" or "Admin") is automatically logged
off when the SITOP PSU8600 web server is inac-
tive for 15 minutes.
Access only permitted via HTTPS:
0: disable
•
255. enable
•
Engineering and remote access
7.6 Cyclic and acyclic data
Data type
Float
Float
Data type
Unsigned32
Data type
Unsigned8
Unsigned8
Unsigned8
Unsigned8
Unsigned8
189