Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
The key benefits of the product include: ● 3-phase 320 to 575 VAC wide-range input ● Power boost during operation 300% for 25 ms (only PSU300M and PSU300B 12 V/20 A) ● No lateral mounting clearances are required ● 150% extra power when loads with high input current are switched on (PSU300M and PSU300B 12 V/20 A only) ●...
Page 4
Overview Ordering data The following device versions are available: Regulated SITOP PSU300M/300B power supply Type Order number 3-phase 400-500 V AC input, 6EP1436-3BA10 Output 24 V DC / 20 A 3-phase 400-500 V AC input, 6EP1456-3BA00 Output 48 V DC / 10 A 3-phase 400-500 V AC input, 6EP1424-3BA00 Output 12 V DC / 20 A...
Table of contents Overview..............................3 Safety notes ............................7 Description, device design, dimension drawing..................9 Device description ........................9 Connections and terminal designation..................10 Potentiometer .......................... 11 Status displays and signaling ....................12 Change-over switch ........................ 15 Block diagram ......................... 16 Dimensions and weight ......................
Page 6
Overload protection in the 24 V output circuit ................ 70 Protection against short-time voltage dips ................71 Protecting against longer power failures ................72 Battery charging with SITOP PSU300B ................. 74 Environment ............................77 Service & Support ..........................79 SITOP PSU300M/300B...
Safety notes WARNING Correct handling of the devices When operating electrical devices, it is inevitable that certain components will carry dangerous voltages. Therefore, failure to handle the units properly can result in death or serious physical injury as well as extensive property damage. Only appropriately qualified personnel may work on or in the vicinity of this equipment.
The output of the device is isolated, no-load proof and short-circuit proof. The LED displays indicate the operating state. The operating state of the device can be processed via the signaling contact. The PSU300B devices are optimized to charge batteries.
Description, device design, dimension drawing 2.2 Connections and terminal designation Connections and terminal designation ① The line input terminals can be used to establish the connection to the supply voltage. ② The output terminals are used to connect to the loads to be supplied (see also Section Installation (Page 35)).
Description, device design, dimension drawing 2.3 Potentiometer Potentiometer ④ The potentiometer on the front of the device is used to adjust the output voltage. The output voltage is set to 12 V, 24 V or 48 V in the factory, and can be adjusted in the range 12 ...
Description, device design, dimension drawing 2.4 Status displays and signaling Status displays and signaling 6EP1436-3BA10 (24 V / 20 A) 6EP1456-3BA00 (48 V/10 A) Operating display LED green for "24 V O.K." LED green for "48 V O.K." Yellow LED for "overload" Yellow LED for "overload"...
Page 13
Description, device design, dimension drawing 2.4 Status displays and signaling Signaling 6EP1436-3BA10 (24 V / 20 A) 6EP1456-3BA00 (48 V/10 A) ⑤ Overload, output voltage < 20.5 V Overload, output voltage < 41 V Yellow LED (only in "constant current" mode) (only in "constant current"...
Page 14
Description, device design, dimension drawing 2.4 Status displays and signaling Signaling 6EP1424-3BA00 6EP1436-3BA20 6EP1437-3BA20 (12 V / 20 A) (24 V / 17 A) (24 V / 30 A) ④ Latching shutdown (only in Latching shutdown (only in Latching shutdown (only in Red LED "Shutdown"...
Description, device design, dimension drawing 2.5 Change-over switch Change-over switch Figure 2-6 Selector switch (example 6EP1456-3BA00 / 6EP1437-3BA20) The two switches A and B are used to influence the output characteristic curve: Switch Parallel operation: Single operation: Delivery state influences the output 'Soft' characteristic curve (see, e.g.
Description, device design, dimension drawing 2.7 Dimensions and weight Dimensions and weight Figure 2-8 6EP1424-3BA00, 6EP1436-3BA20, 6EP1436-3BA10, 6EP1456-3BA00 dimensioned drawing Figure 2-9 Dimension drawing 6EP1437-3BA20 6EP1424-3BA00 (12 V / 20 A) 6EP1437-3BA20 (24 V / 30 A) 6EP1436-3BA20 (24 V / 17 A) 6EP1436-3BA10 (24 V / 20 A) 6EP1456-3BA00 (48 V / 10 A) Dimensions (W ×...
Mounting/disassembly WARNING Installing the device in a housing or a control cabinet The SITOP PSU300M/300B power supply is a built-in device. It must be installed in a housing or control cabinet, to which only qualified personnel have access. The device can be mounted in a control cabinet on standard mounting rails according to EN 60715.
Page 20
Mounting/disassembly WARNING Use in hazardous zones If the devices are to be used in hazardous zones (Ex II 3G Ex nA nC IIC T4) they must be installed in a distribution box with degree of protection IP54 or higher. SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
Mounting position, mounting clearances Standard mounting position The device is mounted on standard mounting rails according to EN 60715. The device must be mounted vertically in such a way that the input terminals and the output terminals are at the bottom to ensure correct cooling. A clearance of at least 50 mm should be maintained above and below the device (maximum depth of the cable duct, 50 mm).
Page 22
Mounting position, mounting clearances 4.1 Standard mounting position Figure 4-3 6EP1424-3BA00: Output current in the standard mounting position Figure 4-4 6EP1436-3BA20: Output current in the standard mounting position Figure 4-5 6EP1437-3BA20: Output current in the standard mounting position SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
Page 23
Mounting position, mounting clearances 4.1 Standard mounting position Figure 4-6 Mounting height derating SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
Mounting position, mounting clearances 4.2 Other mounting positions Other mounting positions For mounting positions that deviate from the standard mounting position, derating factors (reduction of the output power or the permissible ambient temperature) must be observed in accordance with the following diagrams. Note In the case of mounting positions that deviate from the standard mounting position, reduced mechanical resistance of the devices against vibration and shock must be expected.
Page 25
Mounting position, mounting clearances 4.2 Other mounting positions Figure 4-9 6EP1436-3BA10 mounting position (3) Figure 4-10 6EP1436-3BA10 mounting position (4) Figure 4-11 6EP1436-3BA10 mounting position (5) SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
Installation WARNING Hazard due to electric shock Before installation or maintenance work can begin, the system's main switch must be switched off and measures taken to prevent it being switched on again. If this instruction is not observed, touching live parts can result in death or serious injury. Line-side connection The SITOP PSU300M/300B power supply is designed for connection to a 3-phase AC line supply (TN or TT system according to VDE 0100 T 300/IEC 364-3) with a rated voltage of...
Page 36
Installation 5.1 Line-side connection Protection SITOP PSU300M/300B Recommended line-side protection 6EP1436-3BA10 3-pole coupled miniature circuit breaker (IEC 898), characteristic C, 6-16 A or (24 V / 20 A) 3RV2011-1EA10 circuit breaker, setting of the thermal overcurrent trip: 3 A or 3RV2711-1DD10 circuit breaker (branch circuit protection according to UL 489) 6EP1456-3BA00 3-pole coupled miniature circuit breaker (IEC 898), characteristic C, 6-16 A or (48 V / 10 A)
Installation 5.2 Output-side connection Output-side connection At its output, the SITOP PSU300M/300B power supply provides an isolated (= non- grounded) SELV output voltage (Safety Extra Low Voltage). The output of the power supply is no-load, overload, and short-circuit proof. If an overload occurs, the electronic current limiting function limits the output current to a maximum value (see Section Technical data (Page 39)).
Technical data Note Technical data is applicable for a rated input voltage, rated load and +25° C ambient temperature (if nothing else is specified). Input 6EP1436-3BA10 (24 V / 20 A) 6EP1456-3BA00 (48 V / 10 A) Input 3-phase, AC 3-phase, AC Rated voltage value Ue rated 400-500 V...
Page 40
Technical data 6.1 Input 6EP1424-3BA00 6EP1436-3BA20 6EP1437-3BA20 (12 V / 20 A) (24 V / 17 A) (24 V / 30 A) Input 3-phase, AC 3-phase, AC 3-phase, AC Rated voltage value Ue rated 400-500 V 400-500 V 400-500 V Voltage range 320 ...
Technical data 6.2 Output Output 6EP1436-3BA10 (24 V/20 A) 6EP1456-3BA00 (48 V/10 A) Output Regulated, isolated DC voltage Regulated, isolated DC voltage Rated voltage value Ua rated DC 24 V 48 V Total tolerance, static ± Static line regulation, approx. 0,1 % 0,1 % Static load regulation, approx.
Page 42
Technical data 6.2 Output 6EP1436-3BA10 (24 V/20 A) 6EP1456-3BA00 (48 V/10 A) Number of units connected in parallel to increase the power rating, units Output characteristic See Figure 6-3 6EP1436-3BA10 single See Figure 6-4 6EP1456-3BA00 single operation output characteristic curve operation output characteristic curve (Page 44) (Page 44)
Page 43
Technical data 6.2 Output 6EP1424-3BA00 6EP1436-3BA20 6EP1437-3BA20 (12 V / 20 A) (24 V / 17 A) (24 V / 30 A) Short-time overload current 60 A for a short-circuit during operation, typical Duration of the current 25 ms overload capability for a short-circuit during operation Can be connected in parallel to increase the power rating...
Page 44
Technical data 6.2 Output Figure 6-3 6EP1436-3BA10 single operation output characteristic curve Figure 6-4 6EP1456-3BA00 single operation output characteristic curve Figure 6-5 6EP1424-3BA00 single operation output characteristic curve SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
Page 45
Technical data 6.2 Output Figure 6-6 6EP1436-3BA20 single operation output characteristic curve Figure 6-7 6EP1437-3BA20 single operation output characteristic curve The device supplies a constant output voltage until the current limit is reached. If overload occurs, the output current is limited and the output voltage lowered. SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
Page 46
Technical data 6.2 Output Selector switch A closed (parallel operation): The output voltage decreases with increasing output current. Figure 6-8 6EP1436-3BA10 parallel operation output characteristic curve Figure 6-9 6EP1456-3BA00 parallel operation output characteristic curve Figure 6-10 6EP1424-3BA00 parallel operation output characteristic curve SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
Page 48
Technical data 6.2 Output Selector switch B closed (latching shutdown): The device will be shut down if the overload continues for longer than 100 ms. A reset is performed by switching the power supply OFF for at least 5 seconds. Figure 6-13 6EP1436-3BA10 latching shutdown output characteristic curve Figure 6-14...
Technical data 6.3 Efficiency Efficiency 6EP1436-3BA10 (24 V/20 A) 6EP1456-3BA00 (48 V/10 A) Efficiency at Ua rated, Ia rated, approx. 93 % 93 % Power loss at Ua rated, Ia rated, approx. 36 W 36 W 6EP1424-3BA00 6EP1436-3BA20 6EP1437-3BA20 (12 V / 20 A) (24 V / 17 A) (24 V / 30 A) Efficiency at Ua rated, Ia...
Technical data 6.4 Closed-loop control Closed-loop control 6EP1436-3BA10 (24 V/20 A) 6EP1456-1BA00 (48 V/10 A) Dyn. line regulation (Ue rated ±15 %), max. Dyn. load regulation (Ia: 50/100/50%), Ua ± typ. Load step regulation time 2 ms 2 ms 50 to 100 %, typ. Load step regulation time 2 ms 2 ms...
Technical data 6.5 Protection and monitoring Protection and monitoring 6EP1436-3BA10 (24 V/20 A) 6EP1456-3BA00 (48 V/10 A) Output overvoltage protection < 35 V Yes, according to EN 60950 Current limitation, typ. 23 A 11 A Property of the output / short-circuit proof Short-circuit protection Optional constant current characteristic...
Technical data 6.6 MTBF MTBF 6EP1436-3BA10 (24 V/20 A) 6EP1456-3BA00 (48 V/10 A) 6EP1424-3BA00 (12 V/20 A) 6EP1436-3BA20 (24 V/17 A) 6EP1437-3BA20 (24 V / 30 A) Mean Time Between Failures SN29500: > 500,000 hours (typ. 700,000 hours) at 40 °C, rated load, 24-hour opera- tion Mechanical system 6EP1436-3BA10 (24 V/20 A)
Page 56
Technical data 6.7 Mechanical system 6EP1424-3BA00 6EP1436-3BA20 6EP1437-3BA20 (12 V / 20 A) (24 V / 17 A) (24 V / 30 A) Connection system Screw-type terminal Screw-type terminal Screw-type terminal Connections / line supply L1, L2, L3, PE: L1, L2, L3, PE: L1, L2, L3, PE: 1 screw terminal each for 1 screw terminal each for...
Mechanical accessories Device identification labels 20 mm × 7 mm, pastel turquoise 3RT1900-1SB20 Dimension drawing See Section Dimensions and weight (Page 17) CAD data that can be downloaded from the Internet: 6EP1436-3BA10 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00459) 6EP1456-3BA00 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00568) 6EP1424-3BA00 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00680) 6EP1436-3BA20 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00724) 6EP1437-3BA20 (http://www.automation.siemens.com/bilddb/index.aspx?objKey=G_KT01_XX_00683)
Safety, approvals, EMC Safety 6EP1436-3BA10 (24 V/20 A) 6EP1456-3BA00 (48 V/10 A) Primary/secondary galvanic isolation Electrical isolation SELV output voltage Ua according to SELV output voltage Ua according to EN 60950-1 and EN 50178 EN 60950-1 and EN 50178 Protection class Class I Class I Degree of protection (EN 60529)
Safety, approvals, EMC 7.2 Test voltage Test voltage Figure 7-1 Test voltage without auxiliary contact diagram Only the manufacturer can perform the type test and production test; users can also perform the field test. Preconditions for performing the field test: Tests (A) &...
Safety, approvals, EMC 7.3 Approvals Approvals 6EP1436-3BA10 (24 V/20 A) 6EP1456-3BA00 (48 V/10 A) CE marking Yes, (2004/108/EG and 2006/95/EG) Yes, (2004/108/EG and 2006/95/EG) UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259 cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) Explosion protection EPS 12 ATEX 1 442 X IECEx EPS 14.0062X...
Page 62
Safety, approvals, EMC 7.4 EMC 6EP1436-3BA10 (24 V / 20 A) 6EP1456-3BA00 (48 V / 10 A) 6EP1424-3BA00 (12 V / 20 A) 6EP1436-3BA20 (24 V / 17 A) 6EP1437-3BA20 (24 V / 30 A) Line harmonics limit EN 61000-3-2 Class A Generic standards EN61000-6-2...
Ambient conditions 6EP1436-3BA10 (24 V/20 A) 6EP1456-3BA00 (48 V/10 A) 6EP1424-3BA00 (12 V/20 A) 6EP1436-3BA20 (24 V/17 A) 6EP1437-3BA20 (24 V/30 A) Ambient temperature -25°...+70° C with natural convection -10 ...+70° C with natural convection Tested according to: EN 60068-2-1 cold •...
Page 64
Ambient conditions 6EP1436-3BA10 (24 V/20 A) 6EP1456-3BA00 (48 V/10 A) 6EP1424-3BA00 (12 V/20 A) 6EP1436-3BA20 (24 V/17 A) 6EP1437-3BA20 (24 V/30 A) Damaging gases Tested according to: EN 60068-2-42 sulfur dioxide • EN 60068-2-43 hydrogen sulfide • Atmospheric pressure Operation: 1080 ...
Applications Parallel connection to increase power rating To increase the power rating, SITOP PSU300M/300B power supplies of the same type can be directly connected in parallel. The following must be observed: ● The cables connected to each power supply at terminals "+" and "-" must have identical lengths and the same cable cross-sections (or the same impedance) up to a common external connection point (terminal strip) if possible.
Page 66
Applications 9.1 Parallel connection to increase power rating NOTICE Protective circuit for the parallel connection of more than two power supplies When connecting more than two power supplies in parallel, additional measures must be taken to prevent high backward feeding currents in the event of a secondary device fault.
Applications 9.2 Parallel connection for redundancy Parallel connection for redundancy Connecting several SITOP PSU300M/300B power supplies in parallel for redundancy purposes is required if especially high demands are placed regarding the availability of a reliable 24 V power supply. Using the SITOP PSE202U redundancy module, two 24 V power supplies of the same type up to 20 A can be decoupled (Figure 9-2 Redundant configuration with two power supplies and one SITOP PSE202U redundancy module (Page 67)).
Page 68
Applications 9.2 Parallel connection for redundancy Figure 9-3 Redundant configuration with two power supplies and two SITOP PSE202U redundancy modules You can find additional information at: SITOP PSE202U manual (http://support.automation.siemens.com/WW/view/en/42248598) SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
Applications 9.3 Series connection for increased voltage Series connection for increased voltage To achieve an output voltage of 48 V DC, two 24 V SITOP PSU300M/300M power supplies of the same type can be connected in series. In this case, connect the "-" terminal of the first power supply to the "+"...
For variants with single channel signaling, function blocks for evaluation purposes are available for SIMATIC S7-1200/1500/300/400, for STEP 7 Classic and TIA Portal at no charge. You can find additional information at: SITOP PSE200U selectivity module manuals (http://support.automation.siemens.com/WW/view/en/10807226/130000) Figure 9-5 Selectivity module SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
200 ms at 40 A up to 1.6 s for a load current of 5 A. This time can be increased a multiple number of times by connecting buffer modules in parallel; the maximum buffer time is 10 s. You can find additional information at: SITOP PSE201U manual (http://support.automation.siemens.com/WW/view/en/41129219) Figure 9-6 Buffer module SITOP PSU300M/300B...
Using the free-of-charge SITOP DC-UPS software tool, DC-UPS systems can be simply integrated into PC-based automation solutions. This supports further processing of the status signals and safely running down the PC. You can find additional information at: Manual, DC UPS with capacitors (http://support.automation.siemens.com/WW/view/en/48932766/133300) SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
Page 73
– make it easy to integrate operating and diagnostics information into STEP 7 user programs. Preconfigured UPS faceplates for WinCC visualization can be downloaded at no charge. You can find additional information at: DC UPS SITOP UPS1600/UPS1100 Manual (http://support.automation.siemens.com/WW/view/en/84977415) SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
"+" output (connect the anode with "+" output of the SITOP PSU300B and the cathode with the plus pole of the accumulator). The output voltage of the power supply under no load must be set to the end-of-charge voltage plus the voltage drop at the diode.
Page 75
Battery charging with SITOP PSU300B WARNING The SITOP PSU300B power supply is a built-in device. It must be installed in a housing or control cabinet, to which only qualified personnel have access. If SITOP is used as the battery charging device, the VDE 0510 regulations or the appropriate national regulations must be observed and an adequate ventilation of the battery location ensured.
Environment The devices are in conformance with RoHS. As a rule, only non-silicon precipitating materials are used. Disposal guidelines Packaging and packaging aids can and should always be recycled. The product itself may not be disposed of as domestic refuse. SITOP PSU300M/300B Manual, 11.2014, C98130-A7574-A2-2-7629...
● Phone: + 49 (0) 911 895 7222 ● E-Mail (mailto:support.automation@siemens.com) ● Internet: Online support request form (http://www.siemens.de/automation/support-request) Technical documentation on the Internet Operating instructions and manuals for SITOP are available in the Internet: Operating instructions/manuals (http://www.siemens.de/sitop/manuals) SITOP power supply homepage General news about our power supplies is available in the Internet at the SITOP homepage: SITOP (http://www.siemens.de/sitop)
Page 80
Service & Support Contact persons If you have any questions regarding the use of our products, then contact the Siemens contact person in your regional Siemens sales office. You can find these addresses as follows: ● On the Internet (http://www.siemens.de/automation/partner) ●...