Service Call

6.2 SERVICE CALL
6.2.1 SUMMARY
Level
To prevent damage to the machine, the main
machine cannot be operated until the SC has
A
been reset by a service representative (see the
note below).
SCs that disable only the features that use the
defective item. Although these SCs are not
B
shown to the user under normal conditions, they
are displayed on the operation panel only when
the defective feature is selected.
The SC history is updated. The machine can be
C
operated as usual.
Turning the main power switch off then on resets
D
SCs displayed on the operation panel. These are
re-displayed if the error occurs again.
When a Level "D" SC code occurs
When a Level D SC occurs, a screen opens on the operation panel to tell the operator:
An error occurred
The job in progress will be erased
The machine will reboot automatically after approximately 30 seconds.
The operator can wait until the machine reboots automatically or touch "Reset" on the screen to
reset the machine immediately and go back to the copy screen.
M160/M161
Definition
6-2
Reset Procedure
Enter SP mode, go into
SP5-810-001, press
[Execute], and turn the main
power switch off and on.
Turn the main power switch
off and on.
The SC will not be
displayed. Only the SC
history is updated.
Turn the main power switch
off and on.