SC No.
Level
SC No.
Level
SC821-00
D
[0B00]
[0B06]
[50A2]
SM
Error Name/Error Condition/Major Cause/Solution
Reinstall the controller system software.
Replace the RAM-DIMM.
Replace the controller.
Error Name/Error Condition/Major Cause/Solution
Self-diagnostics error: ASIC
[XXXX]: Detailed error code
ASIC register check error
The write-&-verify check has occurred in the ASIC.
Defective ASIC device
Replace the controller board.
ASIC detection error
The I/O ASIC for system control is not detected.
Defective ASIC
Defective North Bridge and PCII/F
Replace the controller board.
Video bridge device (ASIC) register error 1
The CPU detects the video bridge device, but detects error data
from the video bridge device.
Defective I/F between the video bridge device and controller
Replace the controller board.