SC No.
Level
SC547-01
D
SC547-02
D
SC547-03
D
SM
Error Name/Error Condition/Major Cause/Solution
Zero-crossing error (adhered relay contact)
When the fusing relay is in an OFF state, a "zero-crossing
interrupt request" occurs in 50 ms.
Damaged fusing relay (adhered contact)
Turn the main power OFF and then ON.
Replace the harness.
Replace the PC board.
Replace the PSU.
Zero-crossing error (bad relay contact)
If a "zero-crossing interrupt request" does not occur when the
fusing relay is in an ON state, an error results.
- Damaged fusing relay (open contact)
- Failed fusing relay drive circuit
- PSU fuse (24VS) blown
Turn the main power OFF and then ON.
Replace the harness.
Replace the Engine Board.
Replace the PSU.
Replace the fuse.
Zero-crossing error (low frequency error)
The number of zero-crossing interrupts does not reach a certain
value in 500 ms.
The frequency of the commercial power supply is unstable.
Turn the main power OFF and then ON.
Check the commercial power supply.
Replace the harness.
Replace the Engine Board.
Replace the PSU.