Main SP Tables-2
2-930-012
HH:182 Lower
2-930-013
MM:182 Upper
2-930-014
MM:182 Lower
2-930-015
LL:182 Upper
2-930-016
LL:182 Lower
2-930-017
Sensor Standard V
2-930-018
Average Count
2-930-019
Self- Detection
2-930-020
Self-Mixing Time
M160/M161
[0 to 70 / 52 / 1count/step]
Counter for judging the lower limit when
E*
toner remaining in the developer
detected.
[0 to 70 / 33 / 1count/step]
Counter for judging the upper limit
E*
when toner remaining in the developer
detected.
[0 to 70 / 48 / 1count/step]
Counter for judging the lower limit when
E*
toner remaining in the developer
detected.
[0 to 70 / 34 / 1count/step]
Counter for judging the upper limit
E*
when toner remaining in the developer
detected.
[0 to 70 / 46 / 1count/step]
Counter for judging the lower limit when
E*
toner remaining in the developer
detected.
[0.0 to 3.3 / 2.0 / 0.1V/step]
E*
Threshold for judging the detection
result of toner end sensor.
[0 to 255 / 0 / 1count/step]
E*
Result of remaining detection in the
developer.
[- / - / -]
[Execute]
E
Detects forcibly the toner remaining in
the developer.
[0 to 300 / 10 / 1sec/step]
E*
Required time for mixing prior to
forcibly execute remaining detection.