Service Call
SC No.
Level
SC842-01
B
SC No.
Level
SC842-02
B
SC No.
Level
SC853-00
B
M160/M161
Error Name/Error Condition/Major Cause/Solution
Verification error during NAND-Flash update
When starting-up the machine or re-stating it from the energy
saving, the machine reads the state of the NAND-Flash and
detects that there are defective blocks whose amount exceeds
the threshold. This means that the life of the NAND-Flash is
near-end.
Near-end Life of NAND-Flash
Replace the controller board as soon as possible.
Error Name/Error Condition/Major Cause/Solution
NAND-Flash Block-deletion Excess-error
When starting-up the machine or re-starting it from the energy
saving, the machine reads the state of the NAND-Flash and
detects that there are block-deletions whose amount exceeds
the threshold. This means that the life of the NAND-Flash is
near-end.
Near-end Life of NAND-Flash
Replace the controller board as soon as possible.
Error Name/Error Condition/Major Cause/Solution
Bluetooth device connection error
When a Bluetooth hardware device (USB type) is connected
after startup.
A Bluetooth hardware device (USB type) has been connected
after startup.
Connect the Bluetooth hardware device (USB type) before
turning on the main power switch.