[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
5505
error alarm counter decreases by "1" when an SC is not detected during a
set number of copied sheets (for example, default 700 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
5-505-001 -
[Supply/CC Alarm]
5507
Enables or disables the notifying a supply call via the @Remote.
5-507-001 Paper Supply Alarm
5-507-003 Toner Supply Alarm
5-507-004 MaintenanceKIt
5-507-005 DrumLifeRermain
Toner Collection Bottle
5-507-006
Alarm
SM Appendix
[0 to 255 / 15 / 1hundred/step]
C*
0: Alarm Off
[0 or 1 / 0 / 1/step]
Switches the control call on/off for the
paper supply. DFU
0: No alarm
C*
1: Sets the alarm to sound for the
specified number transfer sheets for
each paper size (A3, A4, B4, B5, DLT,
LG, LT, HLT)
[0 or 1 / 1 / 1/step]
Switches the control call on/off for the
stapler installed in the finisher. DFU
C*
If you select "1" the alarm will sound
when the copier detects toner end.
0: Off
1: On
[0 or 1 / 1 / 1/step]
C*
0: OFF
1: ON
[0 or 1 / 1 / 1/step]
C*
0: OFF
1: ON
[0 or 1 / 1 / 1/step]
C*
0: OFF
1: ON