Ricoh M160 Service Manual page 495

Table of Contents

Advertisement

Main SP Tables-5
5491
[Optional Counter]
5-491-001 Detail Option
5501
[PM Alarm]
5-501-001 PM Alarm Level
5-501-002 Original Count Alarm
5504
[Jam Alarm]
5-504-001 -
M160/M161
[0 or 1 / 00000000 / 1/step]
Determines whether to cancel the job
when MK1 keycard is pulled out from
the machine during job.
C*
bit0: Forced Job Canceling
0: On. Cancels the job.
1: Off. Allows operation if MK1 keycard
is pulled out from the machine during
the job.
[0 to 9999 / 0 / 1/step]
0: Alarm off
C*
1 to 9999: Alarm goes off when Value (1
to 9999) x 1000 > PM counter
[0 or 1 / 0 / 1/step]
0: No alarm sounds
C*
1: Alarm sounds after the number of
originals passing through the ADF >
10,000
[0 to 3 / 3 / 1/step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
C*
3: High (6K jams)
Sets the alarm to sound for the
specified jam level (document misfeeds
are not included).
3-82