SC No.
Level
SC634-00
B
SC No.
Level
SC635-00
B
SC No.
Level
SC636-01
D
SM
Error Name/Error Condition/Major Cause/Solution
Counter device error 3
A backup RAM error was returned by the counter device.
Counter device control board or the backup battery of counter
device is defective
Replace the counter device control board.
Replace the backup battery.
Error Name/Error Condition/Major Cause/Solution
Counter device error 4
A backup battery error was returned by the counter device.
Counter device control board or the backup battery of counter
device is defective
Replace the counter device control board.
Replace the backup battery.
Error Name/Error Condition/Major Cause/Solution
IC Card Error (Expanded authentication module error)
Issued when expanded authentication management is set to
"ON" but either of the following occur.
There is no expanded authentication module in the
machine.
The SD card or the file of the expanded authentication
module is broken.
There is no DESS module in the machine.
There is no DESS module in the machine (models on which
the function is optional).
There is no expanded authentication module in the
machine.
The SD card or the file of the expanded authentication
module is broken.
6-21
Service Call