Main SP Tables-2
2-001-100
F:Coefficient:a0
2-001-101
F:Coefficient:a1
2-001-102
F:Coefficient:a2
2-001-103
F:Coefficient:a3
[Reg Correct]
2101
The amount of the correction for the main scan position.
2-101-001 Main Dot
M160/M161
[-500 to -350 / -350 / 1/step]
Displays and adjusts the coefficient a0
used for the C-caluculated function F
E
(Vd, AH, D).
This setting is available when
the bias control is ON.
[0.80 to 1.20 / 1.00 / 0.01/step]
Displays and adjusts the coefficient a1
used for the C-caluculated function F
E
(Vd, AH, D).
This setting is available when
the bias control is ON.
[0.0 to 10.0 / 5.0 / 0.1/step]
Displays and adjusts the coefficient a2
that is of the C-caluculated function F
E
(Vd, AH, D).
This setting is available when
the bias control is ON.
[-20 to 0 / -9.9 / 0.1/step]
Displays and adjusts the coefficient a3
that is of the C-caluculated function F
E
(Vd, AH, D).
This setting is available when
the bias control is ON.
E
[-300 to 300 / 0 / 1dot/step]