1C-3 Engine Electrical Devices:

Oxygen Sensor Heater Inspection

1) Disconnect sensor connector.
2) Using ohmmeter, measure resistance between
terminals "V
" and "GND" of sensor connector.
B
If found faulty, replace oxygen sensor.
NOTE
Temperature of sensor affects resistance
value largely. Make sure that sensor heater is
at correct temperature.
Resistance of oxygen sensor heater
5.0 – 6.4 Ω at 20 °C (68 °F)
3) Connect sensor connector securely.
Tightening Torque Specifications
Fastening part
IAC valve screw
Oil control valve mounting nuts
Oil gallery pipe No.1 bolts
Heated oxygen sensor
Camshaft position sensor bolt
Reference:
For the tightening torque of fastener not specified in this section, refer to "Fasteners Information in Section 0A in
related manual".
Camshaft Position (CMP) Sensor Removal and
S3RH0B1306012
Installation
Removal
1) Disconnect negative cable at battery.
2) Disconnect CMP sensor connector.
3) Remove CMP sensor from cylinder head.
Installation
1) Check that O-ring is free from damage.
2) Check that CMP sensor and signal rotor teeth are
free from any metal particles and damage.
3) Install CMP sensor (1) to cylinder head.
Tightening torque
Camshaft position sensor bolt (a): 10 N·m (1.0
kgf-m, 7.5 lb-ft)
IYSY01131014-01
4) Connect connector to it securely.
5) Connect negative cable to battery.
Specifications
Tightening torque
N⋅m
kgf-m
3.5
11
30
45
10
1
lb-ft
0.35
2.5
1.1
8.0
3.0
21.5
4.5
32.5
1.0
7.5
S3RH0B1306013