Pitney Bowes FastPac DI900 Manuallines page 123

Scan code guidelines
Hide thumbs Also See for FastPac DI900:
Table of Contents

Advertisement

Setting Up an
OMR Scan
Configuration
(continued)
SV61314 Rev. A
IMPORTANT - Defining the Clear Zone (continued)
If the job has no SAF mark:
The machine will ask for the distance from the top of the sheet to the
first mark and the length of the marks. The measurement should be
done as specified, without a clear zone, but there should be a clear area
around the marks with no text or graphics.
For the case of EOC only, the length of the marks will be 2mm (the mini-
mum value that can be entered in the UIM).
TOP OF SHEET
Distance to First Mark
(at least 20mm)
OMR
Marks
at least 20mm*
BOTTOM OF SHEET
NOTES:
Marks should not be placed within 20mm of either the top or bottom of the
sheet. That 20mm includes a clear zone if it is required.
Example: If there are four OMR marks,
and they start 45mm from the top of
page and they take up 7mm in space,
then:
1. The distance to the top of first mark
2. The length of the marks is 7mm.
Length of Marks
(at least 2mm)
* At the time of this writing, we recommend a mini-
mum of 45 mm to last mark because of a scanning
hardware issue Engineering is working on.
Inserter Setup • 7
is 45mm.
7-11