Configuring Fans - Zte ZXA10 C300 Configuration Manual

Optical access convergence equipment
Hide thumbs Also See for ZXA10 C300:
Table of Contents

Advertisement

You can also swap the active and standby switching and control cards through the
following methods:
l
Pull out the active switching and control card.
l
Press the RST button on the active switching and control card.
– End of Steps –

1.3.9 Configuring Fans

This section describes how to configure the fan parameters, such as working mode, speed,
and temperature threshold.
Context
The ZXA10 C300 supports configuration of the following fan parameters:
l
Working mode
Temperature-control mode
à
Fixed-speed mode
à
l
Fan speed level
The options are 0 – 4. This parameter is valid only when the fans are in fixed-speed
working mode.
l
Fan speed percent
The fan speed is the maximum fan speed multiplied with the fan speed percent.
l
High-temperature threshold
When the ambient temperature is higher than the high-temperature threshold, the
ZXA10 C300 reports a high-temperature alarm and disables the interface card. When
the ambient temperature is lower than the high-temperature threshold, the ZXA10
C300 enables the interface card again.
Steps
1. In global configuration mode, configure the fan working mode.
ZXAN(config)#fan control temp_level 30 40 50 60