REP 4.1.14 Lamp Ballast Assembly

Parts List on PL 1.1
Removal
W A R N I N G
H i g h Voltage
Switch off the Scanner and disconnect the Power
Cord.
1. Remove the Left Side Panel (REP 4.1.1).
2. (Figure 1): Disconnect Connector P1 from the Power Distribution
PWB.
Figure 1. Power Distribution PWB
7356 SCANNER
3. (Figure 2): Cut the Cable Ties.
Cable Ties
Figure 2. Removing the Blue Connection Wire
4.
(Figure 3): Disconnect the wire from the Left Lamp Socket.
B
Insert a probe into the
removal slot, and
simultaneously remove
the blue connection
wire.
A
Disconnect the
Lamp Socket
from the
Exposure Lamp
01003A-COB
Figure 3. Disconnecting the Lamp Socket
4/97
4-23
Blue Wire
Blue Connection Wire
01027-COB
REP 4.1.14