LL60/LL61 NVM Fault RAP
This RAP is used for NVM (Non-Volatile
Memory) problems that are indicated by a
status code or a message display. The control
panel displays the message NVM Fault Call
For Assistance. LL60 or LL61 may also be
displayed. The problem may be caused when
the NVM data are corrupted or partially
corrupted. The contents of the NVM do not
agree with the checksum, or the contents of
the NVM do not agree with the shadow
contents.
LL60 • This status code indicates corrupted
data in NVM. Perform steps 1 through 4 of the
procedure.
LL61 -This status code is an indication that an
older version of firmware has been installed.
Ensure that the newest version of firmware is
installed. If the problem persists, perform
steps 1 through 4 of the procedure.
Procedure
The purpose of this procedure is to restore the
printer to normal operation condition. Refer to
DIAGNOSTICS located in Section 6 when
performing this procedure.
LL.60/LL 61 RAP
1. Enter the following diagnostic codes and
record the corresponding data values
displayed on the control panel:
[02-61]
Country Configuration
Electronic Billing Meters value
[0360-2]
[0760]
Delay Between Film Prints
(0860)
Lead Edge Registration value
[0862]
Cut length value
[0903]
Image Module Output Light
Value
[0921-2]
Vhigh
[0921-3]
Illumination (Exposure) value
Remaining Oiler Web Life
[1034]
Fuser Temperature
[1060]
[1062]
Fuser Temperature
[1063]
Fuser Temperature
2.
Enter [0360-1] for NACO printers or [0360-
3] for EO printers to reset the contents of
the NVM to the factory default values.
3.
Enter [0921-6] and then compare the
values recorded in step 1 to previously
recorded values for this printer. Enter the
codes listed in step 1 and change the
default values as required.
NOTE:
If any value recorded in step 1
appears to be incorrect, use the previously
recorded value.
If there Is no previously
recorded value, retain the default value.
1/98
2-8
4. Check/adjust the following:
ADJ 8.1 Vertical Magnification
ADJ 8.2
Lead Edge Registration
ADJ 8.3
Cut Length
ADJ 9.2
Electrostatic Series
ADJ 10.1
Fuser Temperature
NOTE: If the values entered are not retained,
replace the NVM (PL 1.1) and perform steps
2-4 again.