Replacement
1. (Figure 2): Replace the Photoreceptor Seal.
a.
Carefully fold the Photoreceptor Seal along
the perforations.
b.
Slide the Photoreceptor Seal into the
channel, smaller side up, so that the edge of
the Photoreceptor Seal forms a seal with the
inside lip of the channel.
c.
Using a soft, straight tool (a piece of
shimstock works well), carefully push the
seal into the channel, across the entire width
of the Xerographic Module.
2. Replace the Right-hand Seal.
a.
Insert the red stripe end of the Right-hand
Seal underneath the folded Photoreceptor
Seal.
b.
Install the seal fuzzy side up.
c.
Ensure that the seal is flush against the
Xerographic Module Frame.
3. Replace the Cleaner Blade.
a.
Start the Cleaner Blade flush against the left
edge of the Right-hand Seal.
b.
Ensure that the marking, THIS SIDE TO
PHOTORECEPTOR, is to the right.
c.
Push the Cleaner Blade into the channel,
with the Arrow marking to the left.
d.
Ensure that the blade is fully seated in the
channel.
4. Install the first of the three Blade Retainers
approximately one inch from the Xerographic
Module Frame, working to the left.
Photoreceptor
Seal Channel
Photoreceptor
Seal
Cleaner
Blade
Figure 2. Installing the Cleaner Blade Kit
1/98
4-51
Xerographic
Module Frame
Blade
R3012KA
Retainer (3)
REP 9.4