Appendix 10.2 Behavior When The Fast Startup Function Is Enabled - Mitsubishi Electric Q80BD-J71GP21-SX User Manual

Network melsec series/cc-link ie controller
Table of Contents

Advertisement

APPENDICES

Appendix 10.2 Behavior when the fast startup function is enabled

(1) Target operating system
The following operating systems have the fast startup function.
• Windows 10
• Windows 8.1, Windows Server 2012 R2
• Windows 8, Windows Server 2012
(2) Behavior when the fast startup function is enabled
The following explains the behavior of the board when the fast startup function is
enabled.
• The board is not reconnected even after the fast startup.
• After the fast startup, "-28141(9213H) : System sleep error" occurs when
accessing CC-Link IE Controller Network board from the CC IE Control utility or
an application program, which includes MELSEC data link library function.
(3) Corrective action
When the fast startup function is enabled on the personal computer, the setting is
changed by MELSECPowerManager.
For details of MELSECPowerManager, refer to the following section.
Appendix 11
Appendix 10 Behavior When Personal Computer Enters Power Save Mode or Fast Startup
Appendix 10.2 Behavior when the fast startup function is enabled
9
10
11
12
13
14
A
I
App
- 38

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q80bd-j71gp21s-sxQ81bd-j71gp21-sxQ81bd-j71gp21s-sx