APPLICATION FUNCTIONS
(5) Setting required stations and contents for different network system
Request
source
Relay station 1)
Network No.1
12
- 10
12.1 Transient Transmission Function
12.1.2 Routing function
configurations
The stations and contents of the routing parameter setting for the transient
transmission depend on the system configuration.
(a) Single network system
The routing parameter setting is not required for the transient transmission within
the same network.
Request
source
Network No.1
(b) Multiple network system: with two networks
Set the routing parameters only for the request source station.
The route to the request target (Network No.2) is set for the request source
station.
Request
source
Network No.1
(c) Multiple network system: with more than two networks
In the example below, the configuration with four networks is used.
Set the routing parameters for the request source station and the relay stations.
The route to the request target (Network No.4) is set for the request source
station.
The route to the request target (Network No.4) is set for the relay station 1) (the
one which is the closest to the request source).
The route to the request source (Network No.1) is set for the relay station 2) (the
one which is the closest to the request target).
The routes to both the request target (Network No.4) and the request source
(Network No.1) are set for the relay station 3) (the one other than 1) and 2)).
Network No.2
Request
target
Relay station
Network No.2
Relay station 3)
Network No.3
Request
target
Relay station 2)
Network No.4
Request
target