3
SPECIFICATIONS

CHAPTER 3 SPECIFICATIONS

This chapter explains general and performance specifications of CC-Link IE Controller
Network board.
3.1

General Specifications

The following table shows the general specifications of CC-Link IE Controller Network
board.
Item
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Vibration resistance
Shock resistance
Operating atmosphere
*1
Operating altitude
Installation location
*2
Overvoltage category
*3
Pollution degree
Remarks
3
- 1
3.1 General Specifications
Frequency
5 to 8.4 Hz
Compliant with
8.4 to 150 Hz
JIS B 3502 and
IEC 61131-2
Frequency
5 to 8.4 Hz
8.4 to 150 Hz
Compliant with JIS B 3502 and IEC 61131-2 (147 m/s
*1: Do not use or store the board under pressure higher than the atmospheric pressure of altitude 0m.
Doing so may cause malfunction.
*2: This indicates the section of the power supply to which the equipment is assumed to be connected
between the public electrical power distribution network and the machinery within premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300V is 2500V.
*3: This index indicates the degree to which conductive material is generated in terms of the
environment in which the equipment is used.
Pollution degree 2 is when only non-conductive pollution occurs. A temporary conductivity caused
by condensing must be expected occasionally.
The general specifications both CC-Link IE Controller Network board and a
personal computer must be satisfied after installation.
Specification
0 to 55 °C
-25 to 75 °C
5 to 95 % RH, non-condensing
Under intermittent vibration
Constant
acceleration
2
9.8 m/s
Under continuous vibration
Constant
acceleration
2
4.9 m/s
2
, 3 times each in X, Y, Z directions)
No corrosive gases
0 to 2000 m
Inside a control panel
II or less
2 or less
Half amplitude
Sweep count
10 times
3.5 mm
each in X, Y, Z
directions
Half amplitude
Sweep count
1.75 mm