13
ERROR CODES
(3) Equal assignment screen
Error message
The equally assigned end station setting value is outside the
range.
Please input a value within the range XX-YY.
The equally assigned start station setting value is outside the
range.
Please input a value within the range XX-YY.
The equally assigned start device No. setting value is outside
the range.
Please input a value in the range XX-YY.
The setting value for the number of equally assigned points
assigned is outside the range.
Please input a value within the range XX-YY.
The number of identical assigned points setting is outside the
range.
Changing the number of identical assigned points setting
within the range XX-YY.
(4) Routing parameter setting screen
Error message
The Target network No. setting value is outside the range.
Please input a value within the range 1-239.
The relay network No. setting value is outside the range.
Please input a value within the range 1-239.
The relay station No. setting value is outside the range.
Please input a value within the range 1-120.
The Target network Nos. are overlapping.
Please set them so that they do not overlap.
(5) Supplementary setting screen
Error message
The constant scan setting value is outside the range.
Please input a value within the range 1-500.
If not setting it, leave this setting blank.
The setting value for the maximum number of transients for
one station is outside the range.
Please input a value within the range 1-10.
(6) Driver setting screen
Error message
The link refresh cycle setting value is outside the range.
Please input the value within the range 1-1000.
The Driver WDT monitoring time setting value is outside the
range.
Please input a value within the range 1-32767.
The transient timeout monitoring time setting value is outside
the range.
Please input a value within the range 1-360.
13
- 5
13.1 List of Error Messages in CC IE Control Utility
13.1.2 Error messages displayed on the setting screen
Corrective action
Set the value for the equally assigned end station within the
range of XX to YY.
Set the value for the equally assigned start station within the
range of XX to YY.
Set the value for the equally assigned start device number
within the range of XX to YY.
Set the value for the equally assigned points within the range
of XX to YY.
Set the value for the identical assigned points within the
range of XX to YY.
Corrective action
Set the value for the Target Network No. within the range of 1
to 239.
Set the value for the Relay Network No. within the range of 1
to 239.
Set the value for the Relay Station No. within the range of 1
to 120.
Set the Target Network No. not to overlap.
Corrective action
Set the value for the constant scan within the range of 1 to
500, or leave it blank.
Set the value for the maximum number of transients for one
station within the range of 1 to 10.
Corrective action
Set the value for the link refresh cycle within the range of 1 to
1000.
Set the value for the driver WDT monitoring time within the
range of 1 to 32767.
Set the value for the transient timeout monitoring time within
the range of 1 to 360.