PARAMETER SETTINGS
CHAPTER 6 PARAMETER SETTINGS
It is necessary to set the parameters using the CC IE Control utility in order to operate the
CC-Link IE Controller Network.
The following is a flow chart for setting parameters.
6
- 1
Board information settings
(1) Channel No.
151 to 154
Operational settings
(1) Network type
Control station, Normal station
(2) Mode
Such as Online and Offline
(3) Network No.
1 to 239
(4) Group No.
0 to 32
(5) Station No.
1 to 120
No
Is it a control station?
Yes
Network range assignment settings
(1) LB/LW settings
(2) LX/LY settings
(3) Total number of link stations
Set the followings as necessary.
(1) I/O master station settings
(2) Reserved station settings
(3) Driver settings
(4) Supplementary settings
Set the followings as necessary.
(1) Routing parameter settings
(2) Event settings
(3) Target settings
(when accessing the multiple CPU system or redundant
CPU system)
(4) Refresh parameter settings
Write parameters to the personal computer by clicking the
End button of the "Parameter setting" screen.
Section 6.1 Parameter Settings
(Board Information Settings)
Section 6.3.1 LB/LW settings
Section 6.3.2 LX/LY settings
Section 6.3.3 Total number of link stations
Section 6.3.4 Specifying I/O master station
Section 6.3.5 Specifying reserved stations
Section 6.7 Driver Settings
Section 6.6 Supplementary Settings
Section 6.5 Routing Parameter Settings
Section 6.8 Event Settings
Section 6.9 Target Settings
Section 6.10 Refresh Parameter Setting