APPENDICES
No.
Time frame
Personal computer shut down
5
- Driver completion
Driver completion
6
- Before personal computer restart
Personal computer restart
7
- Before CC-Link IE Controller Network
board driver start-up
CC-Link IE Controller Network board
8
driver in operation
After CC-Link IE Controller Network
9
board driver start-up
App
- 11
Appendix 2 Network Status at Power ON/OFF and Board Reset During Data Linking
Appendix 2.1 Network status at power ON/OFF
(c) When the personal computer is restarted (Restarting Windows
Personal
computer
power
ON
ON
ON
*1: The status can be checked on the <<Monitor detail>> tab on the "Logging" screen of the CC IE
Control utility, on the Network diagnostics of GX Developer connected to other station's
programmable controller or at special registers.
*2: The status can be checked on the board list (Start-up) screen of the CC IE Control utility, on the
Network diagnostics of GX Developer connected to other station's programmable controller or at
special registers "Baton pass status of each station (SW00A0 to SW00A7)".
*3: The status can be checked at the "Select station network device status display" on the "CC-Link IE
Controller Network diagnostics result" of the CC IE Control utility, on the Network diagnostics of
GX Developer connected to other station's programmable controller or at special registers "Cyclic
transmission status of each station (SW00B0 to SW00B7)".
*4: When a CC-Link IE Controller Network board is reconnected/disconnected to the CC-Link IE
Controller Network, the all station error may occur for the circuit control period
50ms, Worst value: 100ms). If the all station error occurs, an error is detected in the
communication status (baton pass status) and the data link status (cyclic transmission status) of all
station.
*5: Since the board is reset during the driver operation, a brief loopback occur. An error is also
detected in the communication status (baton pass status) and the data link status (cyclic
transmission status).
*6: The circuit control period is a period to reconstruct the data link when the CC-Link IE Controller
Network board is reconnected/disconnected (such as when the cable is disconnected or the power
is turned from OFF to ON).
Communication
Loop
status (baton
*1
status
*2
pass status)
Normal
Normal
*5
*5
Normal
Normal
Normal
Normal
®
)
Data link status
Data link status
of own station
other than own
(cyclic
station (cyclic
transmission
transmission
*3
status)
status)
Normal
Normal
*5
Normal
Normal
Normal
Normal
*6
(Normal value:
*3
*4

Hide quick links: