NEC Univerge SV8100 System Hardware Manual page 359

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Figure 6-22 NEC Terminal Connection to an IEEE 802.3af PoE Switch
6-32
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
3.
Connect the NEC VoIP telephone to the TEL connector on the ILPA-R
adapter with the LAN cable provided with the adapter.
If a customer-provided cable is used, the total length from the switch to
the telephone should be less than 328 feet.
The adapter can be positioned either closer to the keyset or switch - it
does not matter.
4. Connect a crossover LAN cable to the LAN connector on the ILPA-R
adapter. Plug the opposite end into the switch which is to provide power to
the telephone. Refer to
802.3af PoE Switch.
If a straight-through cable is used, NIC Auto Detection must be
enabled in Programs 10-12-05 (CD-CP00), 84-05-02 (VOIPU) or
85-01-03 (SHUBU).
Figure 6-22 NEC Terminal Connection to an IEEE