The PZ-4COTE consumes four trunk ports ranging between ports
001~200. The CN2 connector provides connection to four analog trunk
ports, which are not polarity sensitive (tip-to-tip, ring-to-ring). The
power failure circuits (CN3), are not polarity sensitive neither.
When using the CD-4COTA blade for loop start
trunks, the PBX ground must
described in Chapter 3 Installing the SV8100
Chassis,
Grounding on page 3-33 or the trunks will not
function correctly.
When
CD-4COTA blades, note the position of the Power
Failure connector (CN3). Do not confuse this
connector as the trunk connector (CN2). Do not wire
an RJ-11 directly to the CD-4COTA interface. Use
the appropriate RJ-61 wiring when connecting to
the CD-4COTA.
Switching from Loop Start to Ground Start is set in
system programming.
Do not wire an RJ-11 directly to the CD-4COTA
interface. Use the appropriate RJ-61 wiring when
connecting to the CD-4COTA.
Table 4-34 PZ-4COTE Maximum Upgrade Capacities