3.2.2
4-26
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
Installation
To install a PZ-ME50 on the CD-CP00:
Do not remove or install the CD-CP00 with the power on.
For installation on the CD-CP00 blade refer to
with Daughter Boards Installed on page
This daughter board does not have any switches which need to be set and
does not require any hardware setting.
Each node in a NetLink network requires the PZ-ME50.
CD-CP00 without the PZ-ME50 installed, supports a
single chassis system only (Six slots only).
CD-CP00 with the PZ-ME50 is required to support a
system with multiple chassis.
CD-CP00 without the PZ-ME50 supports only (One)
CD-LTA (8 Digital Station/2SLT) blade.
Failure to properly install and program ports higher
than 64 (as described below) can corrupt the SV8100
database. When the PZ-ME50 is not physically
installed on the CD-CP00, do not attempt to change
the PCPro database configuration to indicate that the
PZ-ME50 is installed on the CD-CP00, Program ports
64
and
configuration to the SV8100 system. This process can
cause the SV8100 database to be corrupted. Refer to
the
installation/programming procedure.
To properly install and configure the PZ-ME50; first
install the PZ-ME50 on the CD-CP00. To program the
ports above 64 using PCPro, perform a new download
before attempting to program the ports.
If the PZ-ME50 is installed on the CPU at a later date, a
system upgrade must be performed using the
CD-CP00 upgrade procedures. When a PZ-ME50 is
mounted on a CPU, all software upgrades are stored
on this daughter board. If the PZ-ME50 were to be
removed from the CPU, a software upgrade must be
performed to bring the CPU to the latest version.
4-15.
higher,
and
then
next
bullet
Installing the SV8100 Blades
http//vietpro.com.vn
UNIVERGE SV8100
Figure 4-4 CD-CP00 Blade