Offset
Name
address
048H
Pulser operation
maximum speed
049H
04AH
Cooridnate
origin
04BH
04CH
-
04DH
-
04EH
-
04FH
-
Starting address of each positioning parameter
Axis 1
Axis 2
Axis 3
Bank No.
02H
0CH
16H
17-46
Descriptions
The maximum speed when selecting the speed limit for the pulser operation
method.
When the speed calculated by multiplying the pulser input by (Pulser operation
numerator / Pulser operation denominator) is over the specified maximum speed,
the operation is performed at the maximum speed.
Unit: pulse/s (= kHz)
Input range: 0 to 32767000 (pulse/s)
Default: 0
* When zero is set in this area, the operation is performed at the minimum speed
(1 pulse/s (1kHz)) as the maximum speed.
Stores the value of coordinate origin after the home return.
-
-
-
-