17. Put the (so far) unused rubber grommets to the holes in the lead-through plate,
unless you will continue with installing the control cables.
R0...R2
15
18. Secure the cables outside the unit mechanically.
19. Ground the motor cable shield at the motor end. For minimum radio frequency
interference, ground the motor cable shield 360 degrees at the lead-through of
the motor terminal box.
17
Electrical installation 87