130 Maintenance and hardware diagnostics

LEDs

Drive LEDs

There is a green POWER and a red FAULT LED on the front of the drive. They are
visible through the panel cover but invisible if a control panel is attached to the drive.
The table below describes the drive LED indications.
Drive LEDs POWER and FAULT, on the front of the drive, under the control panel / panel
cover
If a control panel is attached to the drive, switch to remote control (otherwise a fault will be
generated), and then remove the panel to be able to see the LEDs
LEDs off
LED lit and steady
No power
Green
(POWER)
Red
(FAULT)
Power supply on the board
OK
Active fault in the drive. To
reset the fault, press
RESET from the control
panel or switch off the drive
power.
LED blinking
Green
Blinking:
Drive in an alarm state
(POWER)
Blinking for one second:
Drive selected on the
control panel when multiple
drives are connected to the
same panel bus.
Red
Active fault in the drive. To
(FAULT)
reset the fault, switch off the
drive power.