152 Technical data
Brake resistor connection data for frames R0...R3
Short-circuit protection
(IEC/EN 61800-5-1, IEC 60439-1,
UL 508C)

Control connection data

External power supply
+24 V DC output
(Term. 10)
Note 2: Radiated emissions are according to C2 with an
internal EMC filter.
Note 3: The internal EMC filter must be connected.
Note 4: Radiated and conducted emissions are according
to category C3 with an internal filter and these cable
lengths.
Note 5: Categories C1 and C2 meet requirements for
connecting equipment to the public low-voltage networks.
The brake resistor output is conditionally short-circuit proof
by IEC/EN 61800-5-1 and UL 508C. For correct fuse
selection, contact your local representative. Rated
conditional short-circuit current as defined in IEC 60439-1.
Maximum power:
Frames R0...R4: 25 W, 1.04 A at 24 V AC/DC ±10%
with an option module
Frames R5...R9: 36 W, 1.50 A at 24 V AC/DC ±10% as
standard
Supplied from an external power supply through option
module CMOD-01 or CMOD-02 with frames R0...R4. With
frames R5...R9 no options are needed.
Terminal size:
Frames R0...R4: 0.2...2.5 mm
Frames R5...R9: 0.14...2.5 mm
Total load capacity of this outputs is 6.0 W (250 mA / 24 V)
minus the power taken by the option modules installed on
the board.
Terminal size:
Frames R0...R4: 0.2...2.5 mm
Frames R5...R9: 0.14...2.5 mm
2