(1.8 °F). The output current can be calculated by multiplying the current given in the
rating table by the derating factor (k):
k
1.00
0.95
0.90
0.85
0.80
0.75
...
-15 °C
-59 °F

IP55 (UL Type 12) drive type -363A-4

In the temperature range +40...45 °C (+104...113 °F), the rated output current is
derated by 1% for every added 1 °C (1.8 °F). In the temperature range +45...50 °C
(+113...122 °F), the rated output current is derated by 2.5% for every added 1 °C
(1.8 °F). The output current can be calculated by multiplying the current given in the
rating table by the derating factor (k):
k
1.00
0.95
0.90
0.85
0.80
0.75
...
-15 °C
-59 °F

IP55 (UL Type 12) drive type -430A-4

The maximum ambient temperature is 35 °C (95 °F).
+40 °C
+45 °C
+104 °F
+113 °F
+40 °C
+45 °C
+104 °F
+113 °F
+50 °C
T
+122 °F
+50 °C
T
+122 °F