Environmental Details; Power Details - Parker AC650V Series Product Manual

Frame 1, 2 & 3
Table of Contents

Advertisement

Environmental Details

Operating Temperature 0C to 40C
Storage Temperature
Shipping Temperature
Product Enclosure
Rating
Cubicle Rating
Altitude
Humidity
Atmosphere
Climatic Conditions
Vibration
Safety
Pollution Degree
Overvoltage Category

Power Details

1-Phase Supply
3-Phase Supply
Supply Power Factor
(lag)
Output Frequency
Switching Frequency
Overload
Supply Short Circuit
Rating
650V AC Drive
-25C to +55C
-25C to +70C
IP20 (UL Open Type) suitable for cubicle mount only
Cubicle to provide 15dB attenuation to radiated emissions between 30-100MHz. It
must also require a security tool for opening
If >1000 metres (3300 feet) above sea level, derate Motor Power Rating by 1% per
100 metres (330 feet) to a maximum of 2000 metres (6561 feet)
Maximum 85% relative humidity at 40C non-condensing
Non flammable, non corrosive and dust free
Class 3k3, as defined by EN50178 (1998)
Test Fc of EN60068-2-6
10Hz<=f<=57Hz sinusoidal 0.075mm amplitude
57Hz<=f<=150Hz sinusoidal 1g
10 sweep cycles per axis on each of three mutually perpendicular axis
Pollution Degree ll (non-conductive pollution, except for temporary condensation)
Overvoltage Category III (numeral defining an impulse withstand level)
220-240V ac ±10%,50/60Hz ±10%, ground referenced (TN) or
non-ground referenced (IT)
220-240V ac or 380-460V ac ±10%,50/60Hz ±10%, ground referenced (TN) or
non-ground referenced (IT)
0.9 (@ 50/60Hz)
0 – 240Hz
Nominal 3kHz
150% for 30 seconds
220-240V 1 product -5000A, 220-240V ac 3 product - 7500A
380-460V 3 product -10000A
Technical Specifications