Recommended module widths for verification of 1D codes
● Minimum module width: 4 pixels
● Recommended module width: 5 pixels
● Maximum module width: 20 pixels
Camera resolution
640 x 480 pixels
(SIMATIC MV440 SR)
1024 x 768 pixels
(SIMATIC MV440 HR)
1600 x 1200 pixels
(SIMATIC MV440 UR)
4.2.7

Formatted output of the verification

One important feature of a verifier is the ability to document results. To allow this, the reader
provides verification reports that can be accessed over the various interfaces.
If a verification report has been configured, this is generated and output each time a read
was successful.
A verification report consists of two parts:
● The verification settings,
● The verification result.
Verification settings
With %v (lower-case "v"), you obtain an output of the all the settings relevant for verification
in the printed order.
All field values are separated by semicolons. The field names are not part of the report.
Field name
Exposure time
Brightness
Brightness offset (coarse)
Brightness offset (fine)
Histogram peak low
Histogram peak high
Cell scaling * 100
Target contrast
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
Min. module width
5 mil
4 mil
3 mil
Calibration code takes up
approximately half the image
height.
Target size: Min. 5 pixels/module
Image processing
4.2 Code verification
Max. module width
Depends on code type,
number of coded characters
Value
0000 ... 9999
0000 ... 0999
-255 ... 0255
-255 ... 0255
0000 ... 0255
0000 ... 0255
0000 ... 9999
0000 ... 0100
65