Siemens SIMATIC MV440 Operating Instructions Manual page 337

Simatic ident code reader system
Hide thumbs Also See for SIMATIC MV440:
Table of Contents

Advertisement

Message
Value
(onboard
PROFINET
diagnostics)
Transfer error
W#16#5007
TCP or RS232
Error - transfer
W#16#5007
error archiving/
MMI
Error - transfer
W#16#5007
error
PROFINET IO
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
Value
Value
(TCP/IP and
(FB45,
RS232)
error_MOBY)
07
0A
07
0A
07
0A
Alarm, fault and system messages
11.2 Reporting diagnostics information
Value
Description
(Ident
profile,
STATUS
byte)
(byte 0,
byte 1,
byte 2)
E1, FE, 04 The send buffer is
full because the
data cannot be sent
in an adequately
short time.
E1, FE, 04 The send buffer is
full because the
data cannot be sent
in an adequately
short time or the
server is not
confirming receipt
of the data in time.
E1, FE, 04 The send buffer is
full because the
data cannot be
queried in an
adequately short
time.
How to remedy the
problem
Reduce the trigger
frequency. With TCP:
Process the results on
the server faster.
A high load on the
network to which the
reader is connected can
also block the transfer of
the data. If necessary,
check the network
connection.
With RS232: Increase
the baud rate. The
image buffer size in
"Program" can also be
increased under Image
acquisition, "Control" tab
to expand the send
buffer.
Reduce the trigger
frequency or reduce the
amount of diagnostic
data to be archived.
Process the results on
the server faster. A high
load on the network to
which the reader is
connected can also
block the transfer of the
data. If necessary, check
the network connection.
Reduce the trigger
frequency or process the
results faster. If
necessary, change the
update time in the
PROFINET
configuration.
335