Siemens SIMATIC MV440 Operating Instructions Manual page 345

Simatic ident code reader system
Hide thumbs Also See for SIMATIC MV440:
Table of Contents

Advertisement

Error code
Message (%s)
(%c)
0014
Only m of the expected number of 1D/2D codes
found in step n
0015
Maximum number of codes per image (m)
exceeded in step n
0016
Exceeded maximum decodable data length in
code m of step n
1006
No Text found in step n
1007
Text too short in step n
1008
Text too long in step n
1009
Quality too low in step n
1010
Match failure in step n
1011
Missing preknowledge for step n
4700
Verification Process Error in step n
4701
Verification Unsupported in step n
4709
Mean light out of range in step n
4710
ISO Verification ECC200 required in step n
4711
ISO Verification aperture too small in step n
4712
ISO Verification aperture too large in step n
4713
ISO Verification insufficient space in step n
4714
ISO Verification failed RDA STEP F1 in step n
4715
ISO Verification failed RDA STEP F2 in step n
4716
ISO Verification failed RDA STEP F3 in step n
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
Alarm, fault and system messages
11.2 Reporting diagnostics information
Description
Only m instead of the expected number of codes was
found in step # n with multicode decoding.
More than the maximum number of codes were found
with multicode decoding (per image: 50 (MV440 UR:
150)).
A maximum of 3001 bytes can be decoded per step.
This amount was exceeded for code #m in step #n.
OCR: No text found in step #n.
OCR: The text found in step #n is shorter than the
configured minimum.
OCR: The text found in step #n is longer than the
configured maximum.
OCR: The text found in step #n is below the
configured quality threshold.
OCR: The match performed in step #n was not
successful.
OCR: There is no string specification available for
step #n.
"Siemens DPM" verification reports: Not enough
space around the data matrix code in step #n.
The selected verification method is not supported for
the code type found in step #n.
"AIM DPM" verification reports: Average brightness
value is out of range (70% ... 86%) in step #n.
Verification according to "ISO15415" and "AIM DPM"
does not support data matrix codes that are not
ECC200. The error occurred in step #n.
The cell size of a data matrix code in step #n is too
large for the set aperture.
The cell size of a data matrix code in step #n is too
small for the set aperture.
"ISO15415" or "AIM DPM" verification reports: Not
enough space around the data matrix code in step #n
"ISO 15415" or "AIM DPM" verification reports an
error during the reference decoding according to
ISO/IEC 16022:2006 in step f), 1 to 6 for page 1. The
error occurred in step #n.
"ISO 15415" or "AIM DPM" verification reports an
error during the reference decoding according to
ISO/IEC 16022:2006 in step f), 1 to 6 for page 2. The
error occurred in step #n.
"ISO 15415" or "AIM DPM" verification reports an
error during the reference decoding according to
ISO/IEC 16022:2006 in step f) 7. The error occurred in
step #n.
343