Siemens SIMATIC MV440 Operating Instructions Manual page 127

Simatic ident code reader system
Hide thumbs Also See for SIMATIC MV440:
Table of Contents

Advertisement

Table 7- 2
SIMATIC MV420
Pin
Color
Signal name
H
Red
24 V DC
G
Blue
0 V
K
Violet
INPUT1
D
Yellow
OUTPUT2
L
Gray/
OUTPUT3
pink
C
Green
ASM TxD_N
B
Brown
ASM TxD_P
A
White
INPUT -
COMMON
E
Gray
OUTPUT -
COMMON
J
Black
STROBE
(OUTPUT)
F
Pink
RS 232 TxD or
ASM RxD_P
M
Red/blue
RS232 RxD or
ASM RxD_N
MV400 push-pull power cable cable pin assignment
See Technical specifications of the interfaces (Page 359).
ASM cable
The connectors are already fitted to the ASM cable.
● Using the ASM cable, you connect the communication modules, for example RF180C
and ASM456.
For SIMATIC MV420, a special ASM cable with M16 socket is available. Refer to the
chapter "Cables" (Page 370).
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
Possible values
TRG
IN_OP, TRD, RDY, READ, MATCH,
N_OK, EXT_1, EXT_2, EXT_3, EXT_4
IN_OP, TRD, RDY, READ, MATCH,
N_OK, EXT_1, EXT_2, EXT_3, EXT_4
P type inputs/outputs:
INPUT - COMMON = 0 V and
OUTPUT - COMMON = + 24 V DC
N type inputs/outputs:
INPUT - COMMON = + 24 V DC and
OUTPUT - COMMON = 0 V
RS232 TxD, ASM RxD_P
RS232 RxD,ASM RxD_N
7.3 Connecting components
Default
Meaning
Power supply
Power supply
TRG
Trigger input
RDY
Freely selectable output
READ
Freely selectable output
TxD_N signal of the
ASM interface
TxD_P signal of the
ASM interface
Reference point 0 V or
24 V for inputs.
Reference point 0 V or
24 V for outputs.
Signal output for
connecting external
flashes
RS232 TXD
RS232 send line or
ASM RxD_P of the ASM
interface
RS232 RXD
RS232 receive line or
ASM RxD_N of the ASM
interface
Connecting
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic mv420