Image processing
4.2 Code verification
Assignment of the numeric grade of ISO/IEC 15415 to the quality levels
Grade (abbreviation)
Axial non-uniformity
(AN_)
Fixed pattern damage (FPD)
Grid non-uniformity (GN_)
Modulation (MOD)
Print growth
Reference decode (RD_)
Symbol contrast (SC_)
Unused error correction (UEC)
54
4
3
≤0.06
≤0.08
This measurement is made in a three-stage process. There is no
direct correlation between the intermediate results and the quality
≤0.38
≤0.50
This measurement is made in a three-stage process. There is no
direct correlation between the intermediate results and the quality
Reference only, no grading
pass
≥0.70
≥0.55
≥0.62
≥0.50
2
1
≤0.10
≤0.12
grade.
≤0.63
≤0.75
grade.
≥0.40
≥0.20
≥0.37
≥0.25
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
0
Comment
>0.12
>0.75
X and Y
fail
<0.20
<0.25