Siemens SIMATIC MV440 Operating Instructions Manual page 339

Simatic ident code reader system
Hide thumbs Also See for SIMATIC MV440:
Table of Contents

Advertisement

Message
Value
(onboard
PROFINET
diagnostics)
Error
W#16#500E
Archiving/
MMI
communication
Error - lamp
W#16#500F
overload
Reserved
W#16#5010
program
number error
Error -
W#16#5011
PROFINET IO
error
Error internal
W#16#5005
file error
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
Value
Value
(TCP/IP and
(FB45,
RS232)
error_MOBY)
14
0C
15
10
16
02
17
-
05
13
Alarm, fault and system messages
11.2 Reporting diagnostics information
Value
Description
(Ident
profile,
STATUS
byte)
(byte 0,
byte 1,
byte 2)
E1, FE, 01 Error in
communication
over the archiving
connection: There
is no TCP
connection, the
server does not
respond within the
set time limit or
violates the
archiving protocol.
E4, FE, 06 The connected
lamp was
overloaded. The
selected or default
"Maximum duty
cycle" from
Options/Lighting
was exceeded.
E6, FE, 04 You are attempting
to save program
number 15 via
digital I/O or
PROFINET IO.
This number
cannot be saved
via these
interfaces.
-
Error in PROFINET
IO communication
E4, FE, 04 An error occurred
while saving to
read-only memory.
How to remedy the
problem
Check the connection to
the server. Make sure
that the data is
processed by the server
in an adequately short
time and that the
protocol is maintained.
Reduce the trigger
frequency, reduce the
exposure time or use a
more powerful lamp.
Select a program
number of between 1
and 14 or user another
interface to save
program number 15.
Make sure that the
parameters for
communication over
PROFINET IO and the
communication partners
are correctly configured
and active. Check the
connection to the I/O
controller.
Please contact technical
support if this error
occurs frequently.
337