Image processing
4.2 Code verification
Field name
Maximum reflectance
Minimum X dimension
Maximum X dimension
Avg. gray scale value
Calibrated exposure time
Calibrated brightness
Light source
Wavelength
List of characteristics
List of characteristics
Note
Verification according to AIM-DPM-1-2006
The standard-compliant verification according to AIM-DPM-1-2006 works with automatic
exposure control. The value output for "Exposure time" in the verification settings therefore
differs from the value of the "calibrated exposure time" and corresponds to the value
selected by the exposure control.
The characteristics list consists of the abbreviation for a quality parameter followed by five
letters. The five letters represent the quality evaluation ([G]ood, [F]air, [P]oor) associated
with the possible grades 0, 1, 2, 3, 4 or F, D, C, B, A (in each case, in this order).
For Siemens DPM, the characteristics list contains 10 entries since all the quality
characteristics can be configured individually here. For all other standards, only the overall
grade is output whose evaluation is relevant for all grades.
66
Value
0000 ... 0100
0000 ... 0999
0000 ... 0999
0000 ... 0255
0000 ... 9999
0000 ... 0999
Name of the lamp
0000 ... 9999
Abbreviation:P[GFP][GFP][GFP]G
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06